Waters
HPLC systems |
| 1 Alliance HPLC system with UV Vis and PDA detection |
Configuration:
- Waters 2695XE Alliance separations module (including column oven, heating/cooling option of sample compartment, degassing unit and autosampler)
- Waters 2487 dual wavelength absorbance detector
- Waters 2996 Photodiode Array Detector
- Software: Empower (control + data acquisition)
|
| 1 Quaternary HPLC system with UV Vis and RI detection |
Configuration:
- Waters 600 controller
- Waters 486 tuneable absorbance detector
- Waters 717+ autosampler
- Waters 410 differential refractometer
- 4 solvent gradient pump
- Column oven
- Software: Empower (data acquisition only)
|
| 2 Quaternary HPLC systems with UV Vis |
Configuration:
- Waters 600 controller
- Waters 486 tuneable absorbance detector
- Waters 717+ autosampler
- 4 solvent gradient pump
- Column oven
|
| 2 Binary HPLC systems with UV Vis |
Configuration:
- Waters 515 pump (2x)
- Waters 2487 dual wavelength absorbance detector
- Waters 717+ autosampler (cooling/heating option with 1 system)
- Column oven with temperature control module
- Degassers
- Software: Empower (control + data acquisition)
|
| Mettler Toledo |
| 2 x AG 204 analytical balances |
Analytical scales connected to a
LC-p45 printer |
| 2 x AG 204DR analytical balances |
Analytical scales connected to a
LC-p45 printer |
| 1x XP205 analytical balance |
Analytical scales (5 decimals) connected to a RS-P42 printer |
| PG 4002-s-DR benchtop scales |
|
| PE 3600 benchtop scales |
|
| S47 Seven Multi |
pH and conductivity measurements |
| FP90 central processor with FP81HT and FP83 HT |
For the determination of melting, boiling and dropping points |
| Thermo electron |
| Avator 360 FT IR (Nicolet) |
- Technique: ATR (Attenuated Total Reflection)
- Enables analysis of films, solids, powders and liquids
- Software: OMNIC 5.2 (for spectra determination, complete with database/library for automatic comparison)
|
| Solaar 969 AA spectrometer (Unicam) |
AAS + AES |
| Interscience |
| Trace GC (Thermo Finnigan) |
- Fitted with 2 FIDs
- Packed and capillary columns
- Digital control (consistently identical conditions)
- GC - PAL autosampler (CTC Analytics)
- Software: EZ Chrom Elite 2.8.3 (control + data acquisition)
|
| Shimadzu |
| GC-2010 |
- Fitted with 2 FIDS
- Capillary columns
- Digital control (consistently identical conditions)
- AOC-5000 autosampler for liquid and headspace injections (CTC analytics)
- Software: GC solution (control + data acquisition)
|
| Perkin Elmer |
| Dual beam spectrophotometer Lambda 2S |
Equipped with an AS90 autosampler |
| Polarimeter 341 |
|
| Erweka |
| Rapid dissolution device DT 80 |
|
| LaboCAT/Shimadzu |
| PharmaTest PTWS310 Semi automated Tablet dissolution Tester |
Connected to a Shimadzu UV-1601 spectrophotometer (with continuous flow device), fitted with a CAT multichannel pump tower and IDIS EE dissolution management software (for control and data acquisition) for the determination of dissolution profiles |
| Hitachi |
| Fluorimeter F 2000 |
|
Applikon/Metrohm
Several different titration systems available: |
| 665 Dosimat with 686 Titroprocessor |
|
| 655 Dosimat with 672 Titroprocessor |
Also suitable for KF titrations |
| 645 Multi Dosimat |
|
| E 719 Titrino S |
|
| Approx. 40 fully tested titration solutions ready for use |
|
| Brookfield Viscometers |
| Type LVTDV-II Digital Viscometer |
|
| Type RVDV-II+ Programmable Viscometer |
|
| PMT |
| APSS 200 Liquid particle counter |
|